Highspeed Data/LAN Cable

__
Category 3 Cable - Plenum


Structured Media Products

Unshielded Twisted Pairs - UTP

Number of Pairs
Calculated Cable O.D.
Impedance
ohms
(Nom.)
Cable Weight LBS.
In.
MM.
2*
0.152
3.86
100
11
3
0.161
4.10
100
13
4
0.200
5.08
100
16
6
0.206
5.23
100
29
8
0.228
5.78
100
34
12
0.271
6.88
100
51
25
0.350
8.89
100
105
50
0.490
12.46
100
217
100
0.700
17.78
100
422
200
0.999
25.37
100
851
300
1.115
28.32
100
1263
* 2 pair 24 AWG is CMP only per UL



Screened Twisted Pairs - ScTP

Number of Pairs
Calculated Cable O.D.
Impedance
ohms
(Nom.)
Cable Weight LBS.
In.
MM.
2*
0.186
4.72
100
16
3
0.198
5.03
100
21
4
0.217
5.51
100
26
6
0.246
6.25
100
36
8
0.278
7.06
100
46
12
0.290
7.37
100
67
25
0.401
10.19
100
116
50
0.551
14.00
100
216
100
0.795
20.19
100
417
* 2 pair 24 AWG is CMP only per UL



Applications: Flame Ratings:
IEEE 802.3
  1BASE5
  10BASE-T
IEEE 802.5
  4 Mbps
IEEE 802.9
  ISO-ETHERNET
IEEE 802.12 -
  100VG-AnyLAN
IEEE 802.3U
  100Base T4
25.6 Mbps ATM
All lower category applications

MPP, CMP
c(UL) or CSA, PCC FT6

Product Design: Industry Standards:
Conductor:

24 AWG Solid Bare Copper per ASTM B-3

Insulation:

MPP Ratio

Shield (ScTP):

Polyester backed aluminum foil with a 24 AWG tinned copper drain wire

Jacket:

UTP low pair count: LSPVC; UTP high pair count: copolymer
ScTP: copolymer

ANSI/TIA/EIA 568A
ANSI/ICEA S-90-661
NEMA WC63.1
Packaging:
1,000 Ft. Reels
1,000 Ft. Reelex Boxes - (Small pair counts only)
Other Put-ups available upon request



Click here for more information on cable substitution & fire resistance

<Back




Order Online RFQ Order Online RFQ


Missing out on Fiber Optic Projects because you don't have trained personnel or the expensive and termination kits needed to do the job correctly?

Fiber Optics Training
We can help click here for more information on our training programs