Category 3 Outside Plant Cable - Voice Grade

__
Category 3 Voice Grade / Highspeed Data
Type CMX Outdoor - CMR


Structured Media Products

Pairs
AWG
Jacket
Color
Feet
Package
O.D.
Inches
Cable Weight LBS.
2
24
Light Olive
Gray
HT
0.16
12
2
24
Ivory
HT
0.16
12
4
24
Light Olive
Gray
PP
0.18
20
4
24
Ivory
PP
0.18
20
Data subject to change without notice. Contact us for the latest information.
NOTE 1:For installations using staple guns the 4 pair construction requires the use of a T-25 size staple whereas the 2 pair can utilize a T-18 size staple.



Typical Electrical Characteristics
24 AWG
DC Resistance (Max)
Ohms / 100m (328 FT) @ 20°C
28.6
Mutual Capacitance (Nom)
pF / 100m (328 FT) @ 1kHz
5.57
Characteristic Impedance
Frequency (f):
Ohms (min-max)
772 kHz
1.0-16.0 MHz
87-117
85-115
Structural Return Loss (SLR)
Frequency (f):
1.0-16.0 MHz
1.0-16.0 MHz
dB (min)
12
12-10 log(f/20)

Frequency
Max Attenuation
dB / 100m (328ft)
Near-End
Crosstalk
dB (Min)
772 kHz
2.2
2.2
1 MHz
2.6
41
4 MHz
5.6
32
8 MHz
8.5
27
10 MHz
9.7
26
16 MHz
13.1
23

Color Code Chart
PAIR No.
RING CONDUCTOR
INSULATION COLOR
TIP CONDUCTOR
INSULATION COLOR
BANDMARK
1
Blue
White
Blue
2
Orange
White
Orange
3
Green
White
Green
4
Brown
White
Brown



Applications:
VOICE
T1
10BASE-T (IEEE 802.3)
4 Mbps Token Ring (IEEE 802.5)
55 Mbps ATM
100BASE VG-AnyLAN
Features
  • UL dual listed Type CMX OUTDOOR-CMR
  • CMX Outdoor rating enables the wire to be used in outdoor applications
  • CMR rating allows for installation in residential, general commercial horizontal wiring and vertical rises in multifloor buildings
Rip Cord
Applied under jacket
Pairing
Two twists per foot minimum
Product Design: Compliances:
Conductor:

24 AWG Solid Bare Annealed Copper

Insulation: 

Polyolefin

Jacket:

Flame retardant PVC
Sequential footage marking

UL Listed Type CMX OUTDOOR-CMR
c(UL) PCC FT4
IBM Type 3

ANSI / TIA / EI 568A (Category 3)
ANSI / ICEA S-90-661(Category 3)
NEMA WC63.1(Category 3)
Packaging:
600' Pull-Pac® Carton (PP)
600' HAT Carton (HT)

Click here for more information on cable substitution & fire resistance