__
Multi-User, Open Office Architecture Cable


Structured Media Products

Non-Plenum
Unshielded Twisted Pairs - UTP Two Legs

Category Of Each 4 Pair Leg
Calculated Cable O.D.
Cable Weight LBS.
In.
MM.
3 X 3
.169 X .368
4.29 X 9.35
40
3 X 5e
.172 X .374
4.37 X 9.50
41
5e X 5e*
.175 X .380
4.45 X 9.65
39
5e X 5e**
.151 X .332
3.84 X 8.43
24
* UL verified to Category 5
** Each leg is a two pair construction

Non-Plenum
Unshielded Twisted Pairs - UTP Three Legs

Category Of Each 4 Pair Leg
Calculated Cable O.D.
Cable Weight LBS.
In.
MM.
3 X 5e X 3
.171 X .573
4.34 X 14.55
60
5e X 3 X 5e
.173 X .579
4.39 X 14.71
59
5e X 5e X 5e*
.175 X .585
4.45 X 14.86
59

* UL verified to Category 5
** Each leg is a two pair construction

Plenum
Unshielded Twisted Pairs - UTP Two Legs

Category Of Each 4 Pair Leg
Calculated Cable O.D.
Cable Weight LBS.
In.
MM.
3 X 3
.171 X .372
4.34 X 9.45
36
3 X 5e
.174 X .377
4.42 X 9.58
42
5e X 5e*
.174 X .378
4.42 X 9.60
45
5e X 5e**
.146 X .322
3.71 X 8.18
27
* UL verified to Category 5
** Each leg is a two pair construction

Plenum
Unshielded Twisted Pairs - UTP Three Legs

Category Of Each 4 Pair Leg
Calculated Cable O.D.
Cable Weight LBS.
In.
MM.
3 X 5e X 3
.174 X .580
4.42 X 14.73
63
5e X 3 X 5e
.174 X .580
4.42 X 14.73
65
5e X 5e X 5e*
.174 X .582
4.42 X 14.78
68
* UL verified to Category 5
** Each leg is a two pair construction

Applications: Flame Ratings:

Primarily developed to lower installation costs

Especially useful for open office architecture between the telecommunication closet and a consolidation point (CP) or mulit-user telecommunication outlet
(MUTO)
(ref EIA / TIA / TSB 75)

Plenum: MPP / CMP, CMG
c(UL) or CSA, PCC FT-6
Non-Plenum: MPR / CMR, CMG
c(UL) or CSA, PCC FT-4

Product Design: Industry Standards:
Conductor:

UTP Construction
24 AWG Solid Bare Copper per ASTM B-3

Insulation:
Plenum
Cat 3 -
Flame retardand PVC
Cat 5e -
MPP rated insulation
Non-Plenum Cat 3 -
PVC
Cat 5e -
Polyethylene
Jacket:

Plenum: Flame retardant color coded PVC
Non-Plenum: Color coded PVC

ANSI/TIA/EIA 568-A-5
ANSI/ICEA S-90-661
NEMA WC63.1
Enhanced Patch Cable: Exceeds TIA / Eia 568-A and proposed Category 5e specification
Exceeds ICEAS-90-661-1997 CAT 5x-100
Patch Cable
Packaging:
1,000 Ft. Reels
1,000 Ft. Reelex Boxes - (Small pair counts only)
Other Put-ups available upon request

Click here for more information on cable substitution & fire resistance

<Back




Order Online RFQ Order Online RFQ


Missing out on Fiber Optic Projects because you don't have trained personnel or the expensive and termination kits needed to do the job correctly?

Fiber Optics Training
We can help click here for more information on our training programs